1.1 Scope
It is mainly used in colloidal interface chemistry, biology, petrochemical industry, material science and other disciplines; it has been widely used in the acquisition of colloidal particle interface image information.
1.2 Instrument parameters
Instrument model: i-speed221
Specifications are: 1280×1024 CMOS image sensor (SVGA); full frame rate: 600fps; chip dynamic range: 90dB; spectral response: 400-900nm; maximum resolution: 1600×1600; bit depth: 10-bit; sensitivity: monochrome 2000 ASA, Color 1000 ASA
1.3 Sample preparation
The samples are stable and non-corrosive.
1.4 Instrument pictures
1.1 Scope
It is mainly used in energy and power engineering, chemical engineering, mineral processing engineering, environmental engineering and other disciplines; it has been widely used in the measurement of flow velocity, flow field display, water flow, air flow, two-phase flow, etc.
1.2 Instrument parameters
Instrument model: 3D-new;
The technical indicators are: measurement accuracy is 1%; laser: single pulse energy 200mj, maximum pulse frequency 10Hz
1.3 Sample preparation
The sample has good reflectivity, and the medium transmits light. The measurement area of the device to be measured should be a transparent material to ensure laser penetration and image capture quality; CCD camera pixels are 2048×2048, so the measurement area should not be too large. In the case of ensuring particle concentration , the shooting area should be within about 150mmx 150mm. For the measurement of the liquid phase, the concentration of the tracer sample is related to the size of the laser intensity nucleus, which is approximately 0.5-1.5g/m3; for the measurement of the gas and liquid phases, in order to ensure the shooting effect, the bubbles The concentration should not be too high.
1.4 Instrument pictures
1.1 Scope
Mainly used in petrochemical multiphase flow and other disciplines; high-precision resistance tomography, the main function is resistance tomography, measuring the volume fraction or concentration of phase components on the cross section.
1.2 Instrument parameters
Instrument model: P2+
Specifications are: accuracy of ±1% conductivity change, speed of 20 ms/frame, up to 8 measurement planes (16 electrodes).
1.3 Sample preparation
You need to equip your own electrodes.
1.4 Instrument pictures
1.1 Scope
It can be used in multi-disciplinary fields to track particles and measure their motion trajectory and speed; currently, it can provide high resolution, ultra-low light sensitivity and recording speed of up to 150,000 frames per second, with its own image analysis tools and 1 microsecond electronic shutter. The ideal analytical tool for advanced research.
1.2 Instrument parameters
Instrument model: i-speed3
Specifications: Olympus custom high-quality CMOS 1280×1024 sensor, full-resolution recording at speeds up to 2000 frames per second, maximum recording speed of 150,000 frames per second, single-color or multi-color options, user-selectable speed of 1 Overall shutter in microseconds.
1.3 Sample preparation
The photographing equipment should be transparent, and the concentration of the discrete phase should not be too high.
1.4 Instrument pictures